Great service & Attention to detail


Response from Trenchless Innovations Inc.:

Thank you for your review, Raul! We are delighted to hear you had a pleasant experience with our team and we are happy they could restore your air ducts for you. We hope you're enjoying the many benefits that air duct lining provides, most notably the cleaner, healthier air in your home. Thank you for choosing Trenchless Innovations for your air duct restoration. We appreciate your business!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for glendale heights, il

 .

. Job Checkin

Trenchless sewer repair service call. Performed CIPP repair on sewer line. Video inspection affirms line is now in good shape.


Bob S.

Bob S. Job Checkin

Under slab leak detection service call. Televised ducts under slab floor. DuCT’s are concrete with metal fittings and connections and have standing water in them. Ran water in several spots and see water movement when kitchen sink is running. Ryan will be speaking with his plumber regarding this issue.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections that are rusted and allowing water to enter the system at times of heavy rains. Downspouts are not extended away from the house and the paver walkway allows for pulling next to the house. Suggest extending all downspouts with solid downspout piping and also redoing the paver walkway to allow for better water run off. Possible sump pit and pump in front of the house if water still persists. After water issue is resolved the ducts should be spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised floor. Ducts are concrete ducts with metal fittings and connections. Slight rusting on the metal fittings. Suggest spray lining ducts with Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

Installing drain tile lower than duct work to stop water from entering ducts, applying our trenchless cast mortar to all underground duct work, and applying two applications of our duct lining material to all underground duct work.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete asbestos ducts with metal fittings and connections that are rusting. Suggest installing drain til in basement to the existing sump pit then spin casting ducts and spray lining ducts with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal couplings. There was standing water in the ducts in the area of the kitchen sink. Ran water in the kitchen sink and saw water entering the duct from the joint. Sink drain needs to be repaired. The downspouts should also be extended away from the house further. After the sink drain line is repaired the ducts should be spray lined with Duct Armor duct lining material to encapsulate the concrete contaminated ducts.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely sealed and the air in the home will be safe for the customer to breathe.


Josh R.

Josh R. Job Checkin

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely sealed and the air in the home will be safe to breathe.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections. Plenum is heavily rusted. Metal joints and fittings are only slightly rusted. Suggest spray lining ducts with Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground duct work. All of the rusted air ducts will be completely sealed and the air in the home will be environmentally safe to breathe.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work and applying our trenchless cast to all the bad metal fittings and spray sealing the entire underground duct work system.


Kevin W.

Kevin W. Job Checkin

Encapsulated underground duct work which was a transite concrete pipe with metal connectors and elbows that were heavily rusted out.


Kevin W.

Kevin W. Job Checkin

Encapsulated all underground asbestos transite air ducts with our duct lining material. The air in the home is now environmentally safe to breathe.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are PVC with metal connections and fittings that are rusting. Downspouts in back of house are run out but are not pitched so water is frozen in downspouts not allowing water to flow properly. Suggest reconfiguring downspouts so there is more pitch so water will not freeze in them. This will reduce the amount of water accumulating next to the house which causes water to enter into the ducts. Once the water issue is resolved the ducts should be spray lined with Duct Armor duct lining material.